Terragene IT27-5YS – Type 6 Steam Sterilization Indicator, 134 °C / 5 min or 121 °C / 15 min (200 pcs)
Terragene IT27-5YS – Type 6 Steam Sterilization Indicator, 134 °C / 5 min or 121 °C / 15 min (200 pcs)
Couldn't load pickup availability
Type 6 chemical indicator for steam sterilization at 134 °C / 5 minutes or 121 °C / 15 minutes.
The Terragene Integron® IT27-5YS monitors specified process conditions inside the sterilization load. Its yellow indicator area turns black when the manufacturer's stated emulation conditions are reached. The indicator supports documented monitoring of suitable steam sterilization cycles, both in medical device reprocessing and in appropriate industrial applications.
Key features
- Type 6 according to ISO 11140-1: Chemical emulating indicator for specified steam sterilization cycles.
- Two specified profiles: 134 °C / 5 minutes (universal cycle) and 121 °C / 15 minutes.
- Result interpretation: Colour change from yellow to black, compared against the manufacturer's reference chart.
- In-load monitoring: For use inside suitable packs, pouches, trays and rigid containers.
- Pack size: 200 indicator strips.
▸Application and result interpretation
Place an indicator inside each pack, pouch or tray to be steam sterilized. In rigid sterilization containers, Terragene recommends placing an indicator in each corner or at least in two diagonally opposite corners. The precise placement must follow the instructions for use and the established monitoring procedure.
After the steam sterilization cycle, compare the colour change with the original manufacturer's reference chart. A complete change from yellow to black indicates that the specified emulation conditions have been reached at the indicator's position. An incomplete or different colour change is a failed result and must be investigated according to the applicable procedure.
The indicator result supplements the monitoring of process data. On its own, it is not proof of sterility and does not replace overall assessment or load release.
▸Applications and limitations
Hospitals, medical device reprocessing units and dental practices: For monitoring suitable steam sterilization cycles when reprocessing medical devices and dental instruments, provided that the selected cycle matches one of the specified profiles.
Pharmaceutical manufacturing and biotechnology: Potential use as supplementary monitoring for defined steam sterilization cycles involving suitable production aids, equipment parts, tubing and other process components.
Medical device manufacturers: Potential use in steam sterilization of suitable components, products and manufacturing aids as part of an established, validated process monitoring system.
Laboratories, research and quality control: Potential monitoring of suitable steam cycles for autoclavable laboratory equipment, plastics, tubing and accessories. The 121 °C / 15-minute profile is particularly relevant to corresponding laboratory applications.
Other industrial applications: The indicator may also be considered for suitable steam sterilization processes in the food industry and other sectors.
Requirements and limitations: The cycle must match the specified profile of either 134 °C / 5 minutes or 121 °C / 15 minutes. Users must assess suitability for their load, indicator placement and monitoring procedure. The stated time–temperature profiles alone do not establish suitability for directly monitoring sterilization of liquids, culture media or waste. The indicator is not intended for other profiles or methods such as dry heat or ethylene oxide. It does not replace process validation or full load release.
▸Technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / product range | Terragene / Integron® |
| Product code | IT27-5YS |
| Indicator type | Type 6 chemical emulating indicator |
| Standard | ISO 11140-1:2014 (according to Terragene IFU) |
| Sterilization method | Steam |
| Specified profile 1 | 134 °C / 5 minutes (universal cycle) |
| Specified profile 2 | 121 °C / 15 minutes |
| Colour change | Yellow to black |
| Dimensions | 70 × 23 mm (IT27 IFU, August 2024) |
| Material | Paper strip laminated on one side and printed with chemical indicator ink |
| Pack size | 200 indicator strips per aluminium foil pouch |
| Shelf life | 5 years from date of manufacture |
| Storage temperature | 10–30 °C |
| Relative humidity | 30–80% |
| Storage conditions | Keep dry and protected from light; do not wet or store near sterilizing agents |
| Post-process result stability | At least 6 months when stored under the specified conditions |
▸Package contents
Included:
- 200 Terragene Integron® IT27-5YS indicator strips (one aluminium foil pouch)
- Manufacturer's instructions for use (IFU), enclosed with every pack
The instructions for use are also available in PDF format under “Documents and downloads”.
▸Documents and downloads
- Instructions for use (IFU) – Terragene IT27-5YS (PDF)
- Technical product description – Terragene IT27-5YS (PDF)
- Colour reference chart – Terragene IT27-5YS (PDF)
The manufacturer's original colour reference is authoritative for interpreting the colour change. Screen colours may differ.